亚洲国产精品成人综合久久久久久久久精品免费看片国产欧美久久久久久精品一区二区三区_成人精品一区二区91毛片不卡_99久久精品无码一区二区毛片免费_亚洲国产成人精品女人久久久国产美女久久久

Pipetting White Paper: Temperature Control Module

Product Introduction The Opentrons temperature control module is a module that can provide a stable temperature for your experiments. It can provide a constant temperature from 4o-95oC and occupies 2 slots on the deck of OT-2. The module is equipped with 1.5-mL, 2.0-mL and PCR aluminum blocks to provide you with different constant temperature needs.

獨(dú)立溫控模塊

Data Interpretation:Accuracy: Refers to the maximum difference between the LCD screen display temperature and the average measured roof temperature. Uniformity: Indicates the temperature change (+/-) measured across the entire top plate surface. Temperature adjustment time: Indicates the total time required for the top plate of the temperature module to reach the required steady-state temperature. Test environment: Data were collected in an experimental environment with a temperature of 22oC and a relative humidity of 37%RH. The above figure shows that the temperature value provided by the temperature control module is relatively stable and accurate, and can reach the required temperature in a short time and provide constant temperature conditions.

Temperature control module with 1.5-2ml aluminum block Equipped with a 1.5-2ml aluminum block, the temperature control module contains 24 well slots and can heat 24 samples at a time. The 1.5-2ml aluminum block provides a more uniform and stable temperature. At the same time, due to the certain thickness and volume of the aluminum block, the temperature adjustment time is longer than that of an independent module, but it is still within the range of high efficiency.

帶鋁塊的溫控模塊

Data Interpretation:Accuracy: refers to the maximum difference between the LCD screen display temperature and the average measured aluminum block temperature. Uniformity: represents the temperature change (+/-) measured across the surface of the aluminum block. Temperature adjustment time: Indicates the total time required for the temperature module aluminum block to reach the required steady-state temperature. Test environment: The data was collected in an experimental environment with a temperature of 22oC and a relative humidity of 37%RH.

Temperature control module with PCR aluminum blockThe temperature uniformity provided by the PCR aluminum block is consistent with that of the 1.5-2ml aluminum block. At the same time, because the aluminum block is smaller in size, the temperature adjustment time is also shorter, and the PCR aluminum block is distributed There are multiple well plates suitable for PCR experiments.

帶PCR鋁塊的溫控模塊

Data Interpretation:Accuracy: refers to the maximum difference between the LCD screen display temperature and the average measured aluminum block temperature. Uniformity: represents the temperature change (+/-) measured across the surface of the aluminum block. Temperature adjustment time: Indicates the total time required for the temperature module aluminum block to reach the required steady-state temperature. Test environment: The data was collected in an experimental environment with a temperature of 22oC and a relative humidity of 37%RH.

Product Usage 1. Environmental conditions and condensation phenomena In order to make the temperature control module and its corresponding aluminum block reach an ideal cold temperature close to 4°C, it is recommended that the laboratory temperature be controlled below 22°C and the relative humidity controlled below 40%. Opentrons has not verified that the temperature module will function properly under laboratory conditions of higher temperature, humidity, or a combination of both. If the temperature of the temperature control module is below room temperature, the operator may observe condensation on the module surface. The exact temperature at which condensation occurs depends on atmospheric temperature and relative humidity conditions. 2. The best heating method. We recommend that users use the water bath heating method to conduct constant temperature experiments. The water bath can make the temperature of the liquid in the slot more uniform, more accurate and more stable. The following figure shows the most suitable aluminum block water bath volume in each hole slot. The Opentrons thermal cycler module is sealed with a silicone sealing film to reduce sample evaporation. The sealing membrane is attached to the lid rather than directly to the module to facilitate pipetting. Each sealing film can be used for approximately 20 temperature cycling applications.

Product Maintenance 1. Cleaning and disinfection steps (be careful not to disinfect by spraying) 1) Turn off the module. Unplug all cables. 2) Moisten a paper towel with alcohol or bleach and wipe the module. Note that you need to avoid disconnecting electronic devices and power supplies during the wiping process. 3) Dry with a dry paper towel. Be careful not to clean the temperature display, power button, power input port, or USB port of the temperature control module. 2. Parts that can be wiped with isopropyl alcohol, ethanol or bleach 1) Aluminum block 2) Heating/cooling top plate 3) Module housing/body 4) Metal sheet housing 5) Insulator

Contact Us

The experienced service team and strong production support team provide customers with worry-free order services.

桃江县| 西平县| 雷山县| 微山县| 山丹县| 九龙坡区| 长宁县| 上饶市| 通道| 莆田市| 松滋市| 平江县| 太原市| 冀州市| 平远县| 大石桥市| 陆河县| 嫩江县| 西华县| 太仓市| 郸城县| 琼海市| 巴彦淖尔市| 黄冈市| 黄平县| 江口县| 霍山县| 东辽县| 平利县| 商丘市| 西华县| 察哈| 乐平市| 舒兰市| 会泽县| 天长市| 九寨沟县| 太保市| 绥滨县| 峡江县| 高安市|