Opentrons Flex, your perfect partner
Unlike other laboratory automation systems available today, Opentrons Flex is an innovative invention that offers high flexibility and versatility, effectively reducing manual operations.
Watch VideoThe next generation of laboratory automation has arrived
Unlike other laboratory automation systems available today, Opentrons Flex is an innovative invention that offers high flexibility and versatility, effectively reducing manual operations.
Watch VideoGive your laboratory automation more freedom:
Extensive API compatible with Design of Experiments programs, including AI drivers
Self-replaceable modular pipettes, plate grippers and upper hardware
Completely open source software and firmware, widely compatible with mainstream reagents and laboratory consumables
Multiple workstation configurations available; easy access to shared protocol resources
With the Flex NGS Workstation, you can automate NGS library preparation on demand, increasing efficiency, reducing errors, and saving hands-on time. You can use any popular reagent on the market to automate all pre-sequencing workflows, including fragmentation- and tagging-based library preparation.
You can select and run the protocols you need from your lab bench using the touchscreen, which also guides you through deck setup and automatic calibration.
The Flex's rotating plate gripper can move plates and tip racks on the deck, or on and between modules, maximizing experimental throughput and extending unattended time.
Opentrons function modules work seamlessly with our pipetting stations and software and can be easily replaced on your own. We offer functional modules such as Opentrons Thermal Cycling Modules, Thermal Oscillation Modules, Temperature Control Modules and Ring Magnetic Stands.
learn more
We offer easily interchangeable 1-, 8-, and 96-channel pipettes for precise and reliable pipetting from 1 to 1000 μL.
1–50 μL
5–1000 μL
1–50 μL
5–1000 μL
5–1000 μL
Choose a protocol that suits your workflow and experience to precisely customize your experimental workflow.
You can create new protocols using our simple and intuitive drag-and-drop interface.
protocol designerYou can browse a large number of open source protocols online through the online protocol library.
protocol libraryWrite your experimental protocols using our open source Python protocol API.
Python APIA team of applied scientists creates optimized custom protocols for you.
Contact usFlexibility to provide the support you need.
87 × 69 × 84 cm / 34.25 × 27 × 33 in (width, depth, height)
Only half your lab bench
88.5 Viewed / 195 Boss
Flex pipettes feature air displacement technology for precise pipetting from 1 to 1000 microliters
Smart sensors enable automatic calibration, real-time positioning and error detection
The Flex gantry can be equipped with any two Flex single-channel or 8-channel pipettes, or a single Flex 96-channel pipette.
Flex pipettes are installation-friendly and you can easily install and replace pipettes
Flex single-channel pipette: 1–50 μL, 5–1000 μL
Flex 8-channel pipette: 1–50 μL, 5–1000 μL
Flex 96-channel pipette: 5–1000 μL
Opentrons Flex plate transfer grippers can transfer well plates, reservoirs and tip racks. Depending on the setup, the swiveling plate grabber can move lab supplies into deck slots, between modules, or into bins.
12 ANSI/SLAS compliant main deck slots (work area with access to pipette and plate grippers)
4 additional slots for tips and laboratory supplies (positioning area, only accessible to transfer plate gripper)
Deck can be reconfigured by removing deck troughs and replacing them with other deck fixtures, including removable bins and module trays
Flex is equipped with a 7-inch LCD touch screen, which is made of anti-scratch and anti-damage LCD material. Users can complete experimental settings by simply touching the screen.
802.11 ac/a/b/g/n dual-band (2.4/5GHz), USB 2.0, Ethernet
Integrated camera (future customization feature)
Power adapter input: 100-240 VAC, 50/60 Hz, 4.0 A / 115 VAC, 2.0 A / 230 VAC
Designed with rigid steel and CNC aluminum
The frame frames the openings for the polycarbonate side windows and front door. Allows for easy removal and integration of external equipment (e.g. robotic arms)
Recommended 20-25°C
Recommended 40-60%RH
Pipette | Measuring range | random error | Systematic error | |||
μl | %D | μl | %CV | μl | ||
1–50 μL | 1 |
±8.00% ±1.50% ±1.25% |
0.08μl 0.15μl 0.625μl |
±5.00% ±0.50% ±0.40% |
0.05μl 0.05μl 0.20μl |
|
5–1000 μL | 5 |
±5% ±0.5% ±0.5% |
0.25μl 0.25μl 1.00μl |
±2.50% ±0.30% ±0.15% |
0.125μl 0.15μl 0.30μl |
Designed with a full polycarbonate shell to limit exposure. Opentrons Flex is not a sterile environment. Optional HEPA/UV accessories are under development.
For guidance on automating the handling of viscous liquids, see our application notes. This data was developed on OT-2, and the practical results are still useful for Opentrons Flex.
Interface with any product that has an API
Opentrons software is open source and users can adapt the software as needed to interface with other products. While all integrations are possible, they all require custom code work, i.e. most customers will need to write custom libraries and install packages that don't come with the robot.
learn moreWindows 10, macOS 10.10 or higher, Ubuntu 12.04 or higher.
Opentrons appUsing Opentrons Flex Tips and Opentrons Flex Filter Tips
Opentrons guarantees the performance of Opentrons Flex tips designed specifically for Opentrons Flex. Opentrons Flex tips do not have a uniform hole size. Opentrons cannot guarantee the performance of third-party tips.
You can use common supplies already in our lab supplies library, or add your own. If your lab consumables fit Opentrons Flex but are not in the lab consumables library, you can add them using our Consumables Creator or have our team assist you in adding them.
learn moreComes with one year warranty
Certification completed (CE, FCC, NRTL, CB, ISO 9001)
Not certified/validated (IVD, GMP)
Flex robot
calibration module
trash can
Spare deck clamp
Spare deck trough, replacement waste bin
Power and zone IEC cables
Ethernet cable
lifting handle
tool kit
Frequently Asked Questions about Opentrons Flex and OT-2 Products規劃,Please click here.
Do I need to know programming knowledge to use Opentrons Flex?
No knowledge of programming is required to use the Opentrons platform. You can create protocols using Opentrons' concise and easy-to-understand protocol design tools. Additionally, our application engineering technical team can build custom protocols for you.
What services can I enjoy by purchasing Opentrons Flex?
On-site installation, remote service and annual preventive maintenance.
What kind of labware is Opentrons Flex compatible with?
Like OT-2, Flex It can support any orifice plate compatible with automation and compliant with ANSI/LAS standards, as well as a wide variety of EP tubes and nut centrifuge tubes, including centrifuge tubes with a capacity of up to 50 mL. You can view all supported laboratory equipment in our Laboratory equipment library.
Do I need a computer to connect to Opentrons Flex? Or can I operate directly on the touch screen?
Users do not need a computer connection to run the protocol. After creating the protocol on your computer, upload it to Flex where it can be operated via the touch screen.
Can I use OT-2 pipettes with Opentrons Flex?
No, OT-2 pipettes are not compatible with Opentrons Flex.
Are the Opentrons Flex side panels removable?
Yes, the side windows and front door of the Opentrons Flex are removable.
Does Opentrons Flex have collision detection?
Opentrons Flex will detect collisions by comparing the actual movement of the embedded motor to the expected movement. For example, if the robot expects 2 motor rotations, but only completes 1 due to a collision (stopping motor movement), the robot will detect the difference between the expected movement and the actual movement. An error message will then appear telling you that recalibration is required.
Can I use one computer to control multiple Opentrons Flex?
Can! The same applies to OT-2.
How many saved protocols can be displayed on Opentrons Flex?
Users can save up to 8 protocols on the Opentrons Flex touch screen.
How much clearance is there in the rear of the Opentrons Flex for power and ventilation?
20 cm (8 inches) of side and back clearance for cables, USB connections, and to dissipate exhaust air from instruments such as thermal cycling modules or temperature control modules.
Welcome to make an appointment for an online demonstration to discuss your experimental needs with a team of professional application scientists.
Book a demoThe experienced service team and strong production support team provide customers with worry-free order services.